FXMSU
DownloadDatasheet PDF FXMSU Optical fibre indoor/outdoor cable Cable characteristics 5 slots 8 slots Tensile strength EN 187000 method 501 N... read more
Description
FXMSU
Optical fibre indoor/outdoor cable

| Cable characteristics | 5 slots | 8 slots | |
| Tensile strength EN 187000 method 501 | N | 500 | 1750 |
| Crush strength / 100 mm (plate) EN 187000 method 504 | N | 4000 | 4000 |
| Crush strength / 25 mm (mandrel) EN 187000 method 504 | N | 650 | 1000 |
| Impact strength EN 187000 method 505 | J | 25 | 30 |
| Min bending radius = during installation/final bending | mm | 140/100 | 260/190 |
| Nominal cable Ø | mm | 9,4 | 13,1 |
| Cable weight | kg/km | 75 | 146 |
| Temperature rating: | Fixed installation -45 °C to +70 °C | |
| Minimum recommended installation temperature -15 °C | ||
| Fire performance | Flame retardant/fire retardant | IEC 60332-1, IEC 60332-3-22 |
| Halogenity | IEC 60754-1 | |
| Acidity of combustion gases | IEC 60754-2 | |
| Conductivity of combustion gases | IEC 60754-2 | |
| Smoke emission density | ||
| Light transmission | IEC 61034-1 ;2xxxxxxxxxxxx | |
| FXMSU | Cable and number of fibres Max 30 fibres |
Diameter of slotted core, mm |
Nominal outer diameter mm |
Approximate weight kg/km |
Minimum bending radius | |
| Part number | during installation, mm |
final installation, mm |
||||
| 10001 | FXMSU 1×4 SML (L) | 5 | 9,4 | 75 | 140 | 100 |
| 10022 | FXMSU 1×6 SML (L) | 5 | 9,4 | 75 | 140 | 100 |
| 10003 | FXMSU 2×4 SML (L) | 5 | 9,4 | 75 | 140 | 100 |
| 10024 | FXMSU 2×6 SML (L) | 5 | 9,4 | 75 | 140 | 100 |
| 10028 | FXMSU 4×6 SML (L) | 5 | 9,4 | 75 | 140 | 100 |
| 14404 | FXMSU 1×4 GKL (L) | 5 | 9,4 | 75 | 140 | 100 |
| 14408 | FXMSU 2×4 GKL (L) | 5 | 9,4 | 75 | 140 | 100 |
| 14410 | FXMSU 3×4 GKL (L) | 5 | 9,4 | 75 | 140 | 100 |
| 14416 | FXMSU 4×6 GKL (L) | 5 | 9,4 | 75 | 140 | 100 |
| 14420 | FXMSU 1×4 SML+1×4 GKL (L) | 5 | 9,4 | 75 | 140 | 100 |
| 14422 | FXMSU 1×4 SML+2×4 GKL (L) | 5 | 9,4 | 75 | 140 | 100 |
| 14424 | FXMSU 2×4 SML+2×4 GKL (L) | 5 | 9,4 | 75 | 140 | 100 |
| 14426 | FXMSU 1×6 SML+3×4 GKL (L) | 5 | 9,4 | 75 | 140 | 100 |
| 14428 | FXMSU 2×6 SML+3×4 GKL (L) | 5 | 9,4 | 75 | 140 | 100 |
| 14384 | FXMSU 1×4 OM3L (L) | 5 | 9,4 | 75 | 140 | 100 |
| 14386 | FXMSU 2×4 OM3L (L) | 5 | 9,4 | 75 | 140 | 100 |
| 14388 | FXMSU 3×4 OM3L (L) | 5 | 9,4 | 75 | 140 | 100 |
| 14398 | FXMSU 4×6 OM3L (L) | 5 | 9,4 | 75 | 140 | 100 |
| 14450 | FXMSU 1×4 SML + 2×4 OM3L (L) | 5 | 9,4 | 75 | 140 | 100 |
| 14451 | FXMSU 2×4 SML + 2×4 OM3L (L) | 5 | 9,4 | 75 | 140 | 100 |
| 14454 | FXMSU 1×6 SML + 3×4 OM3L (L) | 5 | 9,4 | 75 | 140 | 100 |
| 14455 | FXMSU 2×6 SML + 3×4 OM3L (L) | 5 | 9,4 | 75 | 140 | 100 |
| 14541 | FXMSU 1×4 OM4L (L) | 5 | 9,4 | 75 | 140 | 100 |
| 14542 | FXMSU 2×4 OM4L (L) | 5 | 9,4 | 75 | 140 | 100 |
| 14543 | FXMSU 3×4 OM4L (L) | 5 | 9,4 | 75 | 140 | 100 |
| 14564 | FXMSU 4×6 OM4L (L) | 5 | 9,4 | 75 | 140 | 100 |
| 14470 | FXMSU 1×4 SML + 2×4 OM4L (L) | 5 | 9,4 | 75 | 140 | 100 |
| 14472 | FXMSU 2×4 SML + 2×4 OM4L (L) | 5 | 9,4 | 75 | 140 | 100 |
| 14474 | FXMSU 1×6 SML + 3×4 OM4L (L) | 5 | 9,4 | 75 | 140 | 100 |
| 14476 | FXMSU 2×6 SML + 3×4 OM4L (L) | 5 | 9,4 | 75 | 140 | 100 |
| 14478 | FXMSU 4×6 SML + 4×6 OM4L (L) | 5 | 9,4 | 75 | 140 | 100 |
| 10016 | FXMSU 8×6 SML (L) | 8 | 13,1 | 146 | 260 | 190 |
| 14219 | FXMSU 8×6 GKL (L) | 8 | 13,1 | 146 | 260 | 190 |
| 14244 | FXMSU 4×6 SML+4×6 GKL (L) | 8 | 13,1 | 146 | 260 | 190 |
| 14256 | FXMSU 8×6 OM3L (L) | 8 | 13,1 | 146 | 260 | 190 |
| 14264 | FXMSU 4×6 SML + 4×6 OM3L (L) | 8 | 13,1 | 146 | 260 | 190 |
| 14568 | FXMSU 8×6 OM4L (L) | 8 | 13,1 | 146 | 260 | 190 |
Other fiber combinations on request.
Part number for oil resistant SHF2 cable:
4 + code from above table ➞ 4xxxxx