Wind-energiekabel

WILBAwind 0.6/1 kV, Cu, torsion

DownloadDatasheet PDF WILBAwind 0.6/1 kV, Cu, torsion Halogen free single core low voltage cable EPR/PUR Low Voltage Cables Application: EPR/PUR... read more

Description

Download
Datasheet PDF

WILBAwind 0.6/1 kV, Cu, torsion

Halogen free single core low voltage cable EPR/PUR
Low Voltage Cables

Application:
EPR/PUR single core cable designed espe-cially for the use between nacelle and tower of wind energy turbines.

Construction:

  • Cucord flex, class 5asper IEC 60228
    torsion resistant construction
  • EPR insulation, colour black
  • PUR jacket FRNC

Description:

  • very robust and endurable
  • very good resistance to abrasion
  • very good flexibility at low temperatures
  • excellent resistance to high temperatures
  • halogen free
  • flame retardant
  • very good oil and petrol resistance
  • resistance to ozone and weathering
  • nominal voltage U0/U 0.6/1 kV
  • operating voltage max.
    AC U0/U 0.72/1.2 kV
    DC U0/U 0.9/1.8 kV
  • test voltage 3 kV AC
  • min. bending radius 6 x D (D = outer Ø)

Torsion resistance:

  • +/- 150° per metre

Temperature range:

  • -40 °C … + 90 °C
  • short term application up to + 110 °C
  • in case of a short circuit + 250 °C for 5 s

Jacket colour:

  • black, similar to RAL 9005

Applicable standards:

  • construction according to VDE 0250-813
  • IEC 60332-1 flame retardance
  • IEC 60754-1 halogen content
  • IEC 60754-2 corrosivity of fumes
  • IEC 60811-2-1 resistance to oil
  • DIN EN 50396 resistance to ozone
  • ISO 4982-2 UV resistance (test method A)

Remarks:

  • other types upon request
  • version suitable for off-shore applications upon request
Technical data
Cross section
mm2
Part no. Ø d1
approx. mm
ØD
approx. mm
Cu content
kg/km
Weight
kg/km
1 x 120 525000 19,1 22,1 1060 1340
1 x 150 525001 20,6 23,8 1300 1650
1 x 185 525002 22,6 26 1650 1885
1 x 240 525003 26 29,6 2120 2405
1 x 300 525004 28,2 32,2 2620 2960

d1 diameter over insulation
D outer diameter

Cross section
mm2
Admissible tensile
force  max. N
Current carrying capacity1   A
freely suspended
Current carrying capacity1   A
in contact with a surface
Short circuit current
max. kA (1 s)
1 x 120 1800 489 465 17,1
1 x 150 2250 564 536 21,4
1 x 185 2775 644 612 26,4
1 x 240 3600 776 737 34,3
1 x 300 4500 901 856 42,9

1 referring to a single cable which is installed with at least 1 x D distance to the next cable under load at + 30 °C